|
Random Equipment
| Pulse Oximeter > Dolphin > 2100 |
 |
- Automatic self-test at start-up
- Access to user-selectable high and low alarm limits for SpO2 and pulse rate
- A temporary alarm silence feature; silences audible alarms for 120 seconds
- An "all mute" alarm silence feature; silences audible alarms continuously until deactivated
- Status and alarm informational messages appear on the LCD display
- 4 to 12 second SpO2 response averaging modes
- Trend data storage up to 24 hours
- Automatic scaled plethysmographic waveform
- Patented Digital sensor
- Easy-to-read display that presents patient data and status information - shows the SpO2, pulse rate values, a plethysmographic
- waveform, the current high and low SpO2 and pulse rate limit settings, and other messages as appropriate
|
| Ultrasound > GE > Logiq 500 |
 |
- Tissue harmonic imaging.
- B mode, M mode.
- Automatic tissue optimization.
- CW/PW Doppler.
- Digital beam forming with paralell processing.
- Automatic spectral optimization.
- Up to 160 frames CINE scroll memory.
- Image archiving to MO disk or hard drive.
- 15
- Three active probe ports.
|
| Anesthesia > Drager > Narkomed 2B |
 |
- 19.1 and 19.3 vaporizers available.
- ORM Standard ORMC Optional.
- Pneumatic or electronic/ascending or descending bellows.
- Oxygen monitor and cO2 absorber.
- AVE Electronic ventilator.
- Absorber and scavenger.
- Oxygen analyzer.
- Breathing pressure monitor.
- Respiratory volume.
- Centralized alarm and data.
|
| Ultrasound > ATL > HDI-5000 |
 |
- Shared service ultrasound.
- High definition digital broadband beamformer.
- 512 Broadband channels.
- Cine loop (up to 800 frames).
- Power contrast harmonic imaging.
- Tissue harmonics.
- PW?CW Doppler.
- SonoCT & xRES available.
- DICOM available.
|
| Ventilator > Drager > Evita 4 |
 |
- Accomodates adults, children and infants.
- Premature infants with NeoFlow option.
- AutoFlow technology.
- Automatic tube compensation.
- Mask ventilation (optional).
- Power consumption approx 125 Watts.
- Breathing Freq. ftotal, fspon, fmand. (0 to 300 bpm).
- Breathing gas temp 18 °C to 51 °C.
- Dimensions 530 x 315 x 450 mm / 20.9 x 12.4 x 17.7 inches.
- Weight Approx. 50 kg / 64 lbs.
|
| Electrosurgical Unit > Valleylab > Force 2 |
 |
- High Power Digital ESU.
- High performance capabilities.
- Varying degrees of homeostasis.
- Three preset modes.
- Simultaneous independent coagulation.
- Low voltage coagulation.
- Valleylab REM safety.
- Reduces the risk of patient burns.
- Dimensions 8â€h x 13â€w x 21â€l.
- Weight 23lbs.
|
| Pulse Oximeter > Nellcor > N-595 |
 |
- Monitors Neonates through adults
- Convenient selection of alarm limits
- User-selectable fast-averaging mode
- Onscreen viewing of 48 hours of SpO2, and pulse rate trends
|
|